Back to Products

ACLB 125 Dynamic Test System

ACLB 125 Dynamic Test System

  • Regenerative with >90% of energy capture
  • Superior resolution and programmability versus R-L-C loads
  • Fully integrated with isolation and cooling included
  • Lab-Windows based GUI standard ease of programmable parameters and load profile test execution MODBUS RTU, RS232 Interfaces
  • Ideal for testing products designed to function at non-US grids; single phase option available

Specifications

Model ACLB 125
Application Regenerative AC Load/Source
Modes/Features Variable Voltage
Variable Frequency
Adjustable Power Factor (±0.25)
Multi-Unit Paralleling No
Rated Output (kVA) 125
Regenerative Power Supply Mode
Operating Voltage Range - PS 0-528 Vac
Operating Current Range - PS ±151 (3-φ)
Voltage Resolution - PS 46mV
Voltagw Accuracy - PS 1%
Voltage Slew Rate - PS 100V/msec
Load Bank Mode
Operating Voltage Range - LB 0-528 Vac
Operating Current Range - LB ±151 (3-φ)
Current Resolution - LB 20mA
Current Accuracy - LB 1%
Current Slew Rate - LB 5000A/sec
System AC Input
Utility Grid Voltage (Vac) 480, Optional: 208, 400
Specify upon ordering
Utility Grid Frequency (Hz) 50/60
Max Rated Utility Grid Current (Aac) 167A @ 480VAC (60 Hz)
386A @ 208VAC (60 Hz)
Other Specifications
THD for Linear Loads <5.0%
Energy Recovery Efficiency >95%
Grid Isolation Galvanic, Integrated
Cooling Air and Liquid Heat Exchanger, integrated
Audible Noise 65dB
Communications Protocols Modbus, CAN-bus, Analog
Communication Interfaces RS-232, RS-485, CAN-bus, Analog
Weight (lbs) 2500
Dimensions (inches) 52 W x 59.5 D x 83.9 H
Environmental Rated NEMA 1
Standards Designed to UL1741
Back to Products